{"id":2368,"date":"2023-12-18T09:46:07","date_gmt":"2023-12-18T01:46:07","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2368"},"modified":"2024-08-06T09:19:35","modified_gmt":"2024-08-06T01:19:35","slug":"crossflow-cooling-tower-closed-circuit","status":"publish","type":"post","link":"https:\/\/www.gewabintech.com\/fr\/products\/closed-circuit-cooling-tower\/cross-flow-cooling-tower\/crossflow-cooling-tower-closed-circuit\/","title":{"rendered":"Crossflow Cooling Tower Closed Circuit"},"content":{"rendered":"<p><strong>Cross flow Cooling Tower Closed Circuit introduction<\/strong><\/p>\n<p>The&nbsp;cross flow&nbsp;closed cooling tower (also called the evaporative air cooler or the closed cooling tower) places the tubular heat exchanger in the tower, and the cooling effect is ensured by the heat exchange between the circulating air, the spray water and the circulating water.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Characteristics<\/strong><\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"476\" height=\"348\" src=\"\/wp-content\/uploads\/2024\/01\/ae9d3ff59ad25ef57f72.jpg\"  class=\"wp-image-3266\" title=\"Crossflow Cooling Tower Closed Circuit\u63d2\u56fe\" alt=\"Crossflow Cooling Tower Closed Circuit\u63d2\u56fe\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p>\u2606 Improve production efficiency, soften water circulation, no scaling, no clogging, no loss;<\/p>\n<p>\u2606 Extend the life of equipment, ensure reliable and stable operation of equipment, reduce malfunctions, and eliminate accidents;<\/p>\n<p>\u2606 Fully closed cycle, no impurity entering, no medium evaporation, no pollution;<\/p>\n<p>\u2606 Small footprint and saving operating costs<\/p>\n<p>\u2606 Easy to install, move, and arrange, compact structure;<\/p>\n<p>\u2606 Widely used, the medium without corrosion to the heat exchanger can be directly cooled;<\/p>\n<p>\u2606 Low operating cost per life, high initial investment, low operating and maintenance costs;<\/p>\n<p>&nbsp;<\/p>\n<p>1. Axial Fan<\/p>\n<p>Three anti - special motor, &nbsp;Protection class is IP55, The Insulation class F, Axial fan with the Aluminum alloy blade. Start directly.<\/p>\n<p>2. Condensing coils<\/p>\n<p>The heat Exchange tube material is high quality copper tube or the SUS 304, 316L tube. grading and pressure test three times to ensure the closeness.<\/p>\n<p>3. Water pump<\/p>\n<p>we use the special cooling tower water pump, the small volume, light weight, silent mode design.&nbsp;easy maintenance and long life<\/p>\n<p>4. Drift eliminator<\/p>\n<p>PVC material drift eliminator change the Airflow direction three times, recycling the steam utmost to save water. It is easy replace.<\/p>\n<p>5. PVC fill<\/p>\n<p>PVC material, large air volume, small Wind resistance, can prevent the Floating debris enter the Closed cooling tower.&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>FAQ<\/strong><\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"554\" height=\"416\" src=\"\/wp-content\/uploads\/2023\/12\/6a4f945cc2a2b272601d.jpg\"  class=\"wp-image-3267\" title=\"Crossflow Cooling Tower Closed Circuit\u63d2\u56fe1\" alt=\"Crossflow Cooling Tower Closed Circuit\u63d2\u56fe1\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p>1.Q: How can I choose a suitable model?<\/p>\n<p>A: As long as you provide the following information, we can help select the model for you.<\/p>\n<p>2.Q:What is the medium&nbsp;that need to be cooled?<\/p>\n<p>A:Water<\/p>\n<p>3.Q:How to choose a suitable&nbsp;model?<\/p>\n<p>A:&nbsp;wet bulb temperature, inlet temperature and outlet temperature&nbsp;are&nbsp;the necessary datas&nbsp;for calculation.Pls. tell us .then we can choose a suitable model for you.<\/p>\n<p>4.Q:What is your requirement of the condensing coil material and shell&nbsp;material?<\/p>\n<p>A:&nbsp;The coil material of cooling tower is commonly used in SUS304 and&nbsp;SUS316, the shell material is generally galvanized sheet or sSUS04.They&nbsp;can also be selected according to customer needs.<\/p>\n<p>&nbsp;<\/p>\n<p>Hot Tags: crossflow cooling tower closed circuit, suppliers, manufacturers, customized, price, counterflow cooling tower, China Cross Flow Cooling Tower, Wet Cross Flow Cooling Tower, Chilled Water System Cooling Tower, Cooling Tower Systems pric, OEM Industrial cooling towers<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Cross flow Cooling Tower Closed Circuit introduction The&nbsp;cross flow&nbsp;closed cooling tower (also called the evaporative air cooler or the closed cooling tower) places the tubular heat exchanger in the tower, and the cooling effect is ensured by the heat exchange between the circulating air, the spray water and the circulating water. &nbsp; Characteristics &nbsp; \u2606 Improve production efficiency, soften water circulation, no scaling, no clogging, no loss; \u2606 Extend the life of equipment, ensure reliable and stable operation of equipment, reduce malfunctions, and eliminate accidents; \u2606 Fully closed cycle, no impurity entering, no medium evaporation, no pollution; \u2606 Small footprint and saving operating costs \u2606 Easy to install, move, and arrange, compact structure; \u2606 Widely used, the medium without corrosion to the heat exchanger can be directly cooled; \u2606 Low operating cost per life, high initial investment, low operating and maintenance costs; &nbsp; 1. Axial Fan Three anti &#8211; special motor, &nbsp;Protection class is IP55, The Insulation class F, Axial fan with the Aluminum alloy blade. Start directly. 2. Condensing coils The heat Exchange tube material is high quality copper tube or the SUS 304, 316L tube. grading and pressure test three times to ensure the closeness. 3. Water pump we use the special cooling tower water pump, the small volume, light weight, silent mode design.&nbsp;easy maintenance and long life 4. Drift eliminator PVC material drift eliminator change the Airflow direction three times, recycling the steam utmost to save water. It is easy replace. 5. PVC fill PVC material, large air volume, small Wind resistance, can prevent the Floating debris enter the Closed cooling tower.&nbsp; &nbsp; FAQ &nbsp; 1.Q: How can I choose a suitable model? A: As long as you provide the following information, we can help select the model for you. 2.Q:What is the medium&nbsp;that need to be cooled? A:Water 3.Q:How to choose a suitable&nbsp;model? A:&nbsp;wet bulb temperature, inlet temperature and outlet temperature&nbsp;are&nbsp;the necessary datas&nbsp;for calculation.Pls. tell us .then we can choose a suitable model for you. 4.Q:What is your requirement of the condensing coil material and shell&nbsp;material? A:&nbsp;The coil material of cooling tower is commonly used in SUS304 and&nbsp;SUS316, the shell material is generally galvanized sheet or sSUS04.They&nbsp;can also be selected according to customer needs. &nbsp; Hot Tags: crossflow cooling tower closed circuit, suppliers, manufacturers, customized, price, counterflow cooling tower, China Cross Flow Cooling Tower, Wet Cross Flow Cooling Tower, Chilled Water System Cooling Tower, Cooling Tower Systems pric, OEM Industrial cooling towers &nbsp;<\/p>","protected":false},"author":1,"featured_media":2360,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-2368","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cross-flow-cooling-tower"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2368","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gewabintech.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gewabintech.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gewabintech.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gewabintech.com\/fr\/wp-json\/wp\/v2\/comments?post=2368"}],"version-history":[{"count":4,"href":"https:\/\/www.gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2368\/revisions"}],"predecessor-version":[{"id":3929,"href":"https:\/\/www.gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2368\/revisions\/3929"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gewabintech.com\/fr\/wp-json\/wp\/v2\/media\/2360"}],"wp:attachment":[{"href":"https:\/\/www.gewabintech.com\/fr\/wp-json\/wp\/v2\/media?parent=2368"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gewabintech.com\/fr\/wp-json\/wp\/v2\/categories?post=2368"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gewabintech.com\/fr\/wp-json\/wp\/v2\/tags?post=2368"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}